Heater plates for installation between the cells.
Size specifically for ECS LiMax-LFP160 and similar cells.
LFP cells should not be charged at low temperatures. Below 0°C, charging should not occur at all. Below 10°C, the charging current must already be reduced. To protect the cells, they must be warmed up before the actual charging process.
Our heater plates each have a sensor that turns the heater on when the temperature is below 12.5°C and turns it off when the temperature exceeds 14.5°C.
Through the individual monitoring of each heater plate, uniform and rapid heating is ensured.
Normal Heating
For a system with, e.g., 4 cells, at least 2 plates are needed.
For a system with, e.g., 8 cells, at least 4 plates are needed.
Power:
Parameter | 1 Plate | 2 Plates | 4 Plates (for 8 cells) | 8 Plates (for 16 cells) |
Power at 12 V (24 V / 48 V) | 20 W | 40 W | 80 W | 160 W |
Power at 14.4 V (28.8 V / 57.6 V) | 30 W | 60 W | 120 W | 240 W |
Parameter | 1 Plate | 5 Plates | 9 Plates (for 8 cells) | 17 Plates (for 16 cells) |
Power at 12 V (24 V / 48 V) | 20 W | 100 W | 180 W | 340 W |
Power at 14.4 V (28.8 V / 57.6 V) | 30 W | 150 W | 270 W | 510 W |
Switch-on Temperature | < 12.5 °C |
Switch-off Temperature | > 14.5 °C |
Dimensions (H x L x W) | 176 x 174 x 1.6mm |
For cells with dimensions (H x L) | 165 x 174 mm |
Additional insulation for the heating. It is required at the beginning and at the end of the battery stack (the arrangement can be seen in the second image, on the left and right).
This Product was added to our catalogue on 16/09/2021.