Hole:
The fuses have a factory-made slot for M6. On request, we can supply them drilled out to M8.
Attention: Customer-specific modified components are excluded from exchange.
With M8 hole suitable for Victron Lynx Distributor M8, but not all cable lugs fit.
For example, the Klauke cable lugs are often too long. Check dimensions. The Cembre A series, for example, is more suitable here.
Please select the desired hole above.
Note on delivery time:
The standard delivery time is (2-3 days as stated above) if the item is in stock. If you receive a message that the item(s) are not in stock in the desired quantity, you can still place the order. We will then reserve the corresponding quantity and will dispatch it immediately when we next receive the goods. Please contact us for the expected delivery times.
Note for international sales.
Delivery time might be longer. Not all countries are supported by the online shop system. If you receive a message from the store system that the shipping costs cannot be calculated, please contact us by e-mail. We will then prepare an offer.
Attention:
To select the fuses, you need electrical engineering knowledge! Please do not order if you do not have the appropriate training.
Please note that a higher current than the rated current can flow for a certain time in all fuses. All components in the circuit must be designed for this current.
Note the maximum voltage and disconnecting capacity!
Sometimes we see fuses are mounted directly on a battery cell terminal. We do NOT recommend this without consulting the cell manufacturer. Like all fuses, this fuse heats up when the cut-off current is close. The heat input into the cell can have negative effects. Use fuse holders.
Ambient temperatures influence the cut-off point.
FAQ:
Q: Shouldn't the fuse be as close as possible to the battery? So best on the battery block?
A: Due to the heat input, we do not recommend mounting it directly on a cell. Use fuse holders. You can make the connection to the fuse short-circuit-proof by laying the cables in such a way that a short circuit before the fuse is inpossible.
It is also possible to use double-insulated cables. We recommend NSGAFöü, for example. This is considered short-circuit-proof and has an increased temperature resistance.
This Product was added to our catalogue on 23/07/2024.