Adler Electric AB1 - Level Mount

Adler Electric AB1 -  Level Mount
For a larger view click on the thumbnail
from 7,74 EUR
VAT excl. excl. Shipping costs
Rated current
Hole
Add to cart

Shipping time: 2-3 Working Days
MPN: AB1xxxx100
Manufacturer: ADLER Elektrotechnik Leipzig



  • Details
  • Downloads
  • Customer-tip

Products description

 Adler AB1 series ESS fuses are engineered and manufactured for use in Industrial ESS and Power Distribution Protection, made from the highest quality materials and tested to the highest standards. With rated currents from 50A to 300A with abreaking capacity of 20kA @ 200V DC

FEATURES:
• 200 Vdc fuse
• Rated Current: 50-300 A
• Breaking Capacity: 20 kA
• Dimensions: 22x29mm
• QR code marks on each fuse for traceability

AGENCY INFORMATION:
• Ref. to: UL 248-13; IEC 60269-4
• Approval: UL (File: E485737)
• Manufactured under IATF 16949 quality system
• RoHS and REACH Compliant

APPLICATIONS:
• ESS and BESS circuit protection
• Power storage protection

Hole:
The fuses have a factory-made slot for M6. On request, we can supply them drilled out to M8.
Attention: Customer-specific modified components are excluded from exchange.
With M8 hole suitable for Victron Lynx Distributor M8, but not all cable lugs fit.
For example, the Klauke cable lugs are often too long. Check dimensions. The Cembre A series, for example, is more suitable here.
Please select the desired hole above.

Attention:
To select the fuses, you need electrical engineering knowledge! Please do not order if you do not have the appropriate training.
Please note that a higher current than the rated current can flow for a certain time in all fuses. All components in the circuit must be designed for this current.
Note the maximum voltage and disconnecting capacity!
Sometimes we see fuses are mounted directly on a battery cell terminal. We do NOT recommend this without consulting the cell manufacturer. Like all fuses, this fuse heats up when the cut-off current is close. The heat input into the cell can have negative effects. Use fuse holders.
Ambient temperatures influence the cut-off point.

FAQ:
Q: Shouldn't the fuse be as close as possible to the battery? So best on the battery block?
A: Due to the heat input, we do not recommend mounting it directly on a cell. Use fuse holders. You can make the connection to the fuse short-circuit-proof by laying the cables in such a way that a short circuit before the fuse is inpossible.
It is also possible to use double-insulated cables. We recommend NSGAFöü, for example. This is considered short-circuit-proof and has an increased temperature resistance.

File

DatasheetDownload1.55 MB
Datasheet

Customers who bought this product also bought the following products:

Fuse NH000
NH000 Fuse Melt; gG; Ceramics,industry; 500VAC; 220VDC
Shut-off capacity: 25kA (for DC up to 220V)
Thus as main fuse suitable for most lithium battery systems.
Possible shut-off currents: 32 A , 40 A, 50 A, 63 A, 80 A (please select above)
Shipping time: 2-3 Working Days
7,02 EUR
19 % VAT incl. excl. Shipping costs
NSGAFÖU  70mm²
NSGAFÖU cable short circuit and earth-fault-proof. Colour: black.  Voltage Rating (Uo/U): 1.8/3kV.
 
Shipping time: 2-3 Working Days
from 18,92 EUR
19 % VAT incl. excl. Shipping costs
greenFuse AE5 500V AUTOMOTIVE
Shipping time: 2-3 Working Days
from 12,00 EUR
VAT excl. excl. Shipping costs
LS_1POL_X
Line circuit breakers for DC systems
- 1 pole
- 10 kA switch-off capacity
- Possible shut-off currents 1A, 2A, 4A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A , 40A, 50A, 63A 
Shipping time: 2-3 Working Days
from 9,50 EUR
19 % VAT incl. excl. Shipping costs

This Product was added to our catalogue on 23/07/2024.

Quick purchase

Please enter the article no. from our catalogue.

Welcome back!
Manufacturer
ADLER Elektrotechnik Leipzig
Shipping country