SmartPro is the central component of our BMS. Together with our LiPros (cell voltage measurement, cell temperature measurement and charge equalization) and our PowerPro (fuse, secondary protection and main switch), it forms a highly accurate, powerful and multi-redundant battery management system. SmartPro combines high-precision current measurement to determine the SOC with high-performance, charge and load control. SmartPro is equipped with surge arresters that safely dissipate voltage peaks caused by line inductances. SmartPro can be flange-mounted on the side of the battery pack. The input is located at the top on the edge of the circuit board so that simple installation and wiring is possible.
Main functions:
| SmartPro 12-115 | SmartPro 24-115 | SmartPro 48-115 | Unit | |
|---|---|---|---|---|
| Electrical data | ||||
| Nominal system voltage | 12 | 24 | 48 | V |
| Max operating voltage | 15 | 30 | 60 | V |
| Max Continuous current | 125 | 125 | 125 | A |
| Max peak current 100µs | 650 | 650 | 650 | A |
| Max Continuous power | 1500 | 3000 | 6000 | W |
| Switch-on resistance | < 1 | < 1.25 | < 1.5 | mΩ |
| Overvoltage protection | ||||
| Breakdown voltage | 17.5 | 35 | 70 | V |
| Total power Surge protection (Pppm) (Peak pulse power dissipation with a 10/1000 μs waveform). |
10 | 20 | 40 | kW |
| Control system | ||||
| Control voltage LVP, OVP | 4.7 to 60 | V | ||
| Power consumption | 0.1 typ. | w | ||
| Additional output | ||||
| Max Switching voltage | 15 | 30 | 60 | V |
| Max Switching current | 10 | 5 | 2.5 | A |
| Functions | Programmable for heating control, SOC display, error message, others on request | |||
| Current measurement accuracy | ||||
| Measuring range current | ±125 | A | ||
| Resolution | 0.001 | A | ||
| Total maximum error (Contains Offset error + linearity error + temperature drift |
< 0.04 FS ( von -10 to +50 °C) |
% | ||
| Offset error | < 0.01 FS ( von -10 to + 50 °C) | % | ||
| Voltage measurement accuracy | ||||
| Measuring range battery voltage | 15 | 30 | 60 | V |
| Total maximum error (Contains offset error + linearity error + temperature drift ) |
0.1 FS | % | ||
| Mechanical data | ||||
| Dimensions (LxWxH) without plug |
160 mm x 146 mm x 35 mm | mm | ||
| Slotted holes for M8 threaded rod Distance: 123 mm for cell width up to max 115 mm |
mm | |||
| Weight | 300 | g | ||
| Terminal bolt outputs | M6 Distance: 80 |
mm | ||
| Connection terminals inputs | M6 Distance: 62 mm |
mm | ||
| Protection class | IP00 | |||
from 261,80 EUR